{"title":"Electrical Oil Pumps","description":"","products":[{"product_id":"12-volt-dc-oil-pump","title":"12 Volt DC Oil Transfer Pump","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\nThe DITI17520100 is a 12V DC Oil Transfer Pump featuring an electric self-priming rotary external gear pump equipped with a bypass valve. Powered by a brush motor with IP55 protection class (CEI EN 60034-5), it delivers 10 litres per minute at 4 bar pressure and is designed for intermittent use in professional oil transfer applications. The pump is suitable for oils with a viscosity of 50 to 600 cst at working temperature and can be installed horizontally or wall-mounted to suit a range of workshop configurations.\n\u003c\/p\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDITI17520100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eVoltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e12V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePower\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e150W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCurrent\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e40A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFlow Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e10 LPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePressure\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e4 bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eInlet \/ Outlet\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e3\/4\" BSP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eRated Speed\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e2900 RPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMotor Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eBrush motor, continuous current, low voltage, intermittent cycle, closed type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMotor Protection Class\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eIP55 (CEI EN 60034-5)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePump Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eElectric self-priming rotary external gear pump with bypass valve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFluid Viscosity (Allowed)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50–600 cst at working temperature\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e-10°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eRelative Humidity (Max)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e90%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eWorking Cycle\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eIntermittent — 30 minutes maximum under conditions of maximum back pressure\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eNoise Level\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eMax 70 dB(A) at 1 metre\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eSelf-priming — able to draw oil from the tank even when the suction hose is empty on start-up\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eEquipped with bypass valve for automatic pressure relief\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIP55 motor protection class for reliable operation in workshop environments\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMultiple installation orientations supported — horizontal or wall-mounted (pump body upwards, sideways, or with check valve)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMaximum priming height of 2.5 metres\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eAlso available in 24V (DITI17520101) and US NPT configurations (DITI17520102, DITI17520103)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eThe information contained in this data sheet is based on data considered to be accurate. No warranty is expressed or implied regarding the accuracy of this data. Product specifications and availability are subject to change without notice. Lube Control Pty Ltd accepts no responsibility for any loss or damage arising from the use of this information.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBE CONTROL","offers":[{"title":"12 Volt Dc Oil Pump","offer_id":50280588968211,"sku":"DITI17520100","price":446.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/DITI17520100_jpg.png?v=1736314298"},{"product_id":"240-volt-high-volume-gear-oil-pump","title":"240 Volt High Volume Gear Oil Pump","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\nThe DITI17320400 is an AC Gear-type Oil Pump featuring an electric self-priming rotary internal gear pump equipped with a bypass valve. Powered by a 4-pole asynchronous motor with IP55 protection class, the motor is self-ventilating and flange-mounted directly to the pump body for a compact and robust design. Operating at 230V AC \/ 50Hz with a nominal power of 1100W, it delivers 40 litres per minute at up to 10 bar maximum pressure — suitable for oils with a viscosity of 500 to 2000 cst at working temperature. Under normal operating conditions the pump can function continuously with no cycle limitations.\n\u003c\/p\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDITI17320400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCurrent Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eVoltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFrequency\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eNominal Power\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1100W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMaximum Pressure\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e10 bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFlow Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e40 LPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePump Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eElectric self-priming rotary internal gear pump with bypass valve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMotor Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eAsynchronous, 4-pole, closed type, self-ventilating, flange-mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMotor Protection Class\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eIP55\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFluid Viscosity (Allowed)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e500–2000 cst at working temperature\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e-10°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eRelative Humidity (Max)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e90%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eWorking Cycle\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eContinuous — no limitations under normal operating conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMinimum Hose Diameter\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1\" (suction and delivery)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eNoise Level\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eMax 70 dB(A) at 1 metre\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eSelf-priming — able to draw oil from the tank even when the suction hose is empty on start-up\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eEquipped with bypass valve for automatic pressure relief\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIP55 motor protection class — suitable for demanding professional workshop environments\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eContinuous duty cycle under normal operating conditions — no work cycle time limit\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eExcellent suction capacity — flow rate\/back pressure curve remains stable even at high suction pressure values\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMultiple installation orientations supported — horizontal base, pump body upwards, or pump body aside\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eAlso available in 380V\/50Hz (DITI17320401) and 120V\/60Hz US configurations (DITI17320500, DITI17320501)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eThe information contained in this data sheet is based on data considered to be accurate. No warranty is expressed or implied regarding the accuracy of this data. Product specifications and availability are subject to change without notice. Lube Control Pty Ltd accepts no responsibility for any loss or damage arising from the use of this information.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBE CONTROL","offers":[{"title":"240 Volt High Volume Gear Oil Pump","offer_id":50280589033747,"sku":"DITI17320400","price":1229.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/DITI17320400.png?v=1736314339"},{"product_id":"240-volt-high-flow-gear-oil-pump","title":"240 Volt High Flow Gear Oil Pump","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\nThe DITI17320140 is an AC Gear-type Oil Pump featuring an electric self-priming rotary internal gear pump equipped with a bypass valve. Powered by a single-phase, 4-pole asynchronous motor with IP55 protection class, the motor is self-ventilating and flange-mounted directly to the pump body. Operating at 230V AC \/ 50Hz with a nominal power of 750W, it delivers 14 litres per minute at up to 12 bar maximum pressure — suitable for oils with a viscosity of 50 to 2000 cst at working temperature. Under normal operating conditions the pump can function continuously with no cycle limitations.\n\u003c\/p\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDITI17320140\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCurrent Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eVoltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFrequency\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eNominal Power\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e750W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMaximum Pressure\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e12 bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFlow Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e14 LPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePump Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eElectric self-priming rotary internal gear pump with bypass valve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMotor Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eAsynchronous, single phase, 4-pole, closed type, self-ventilating, flange-mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMotor Protection Class\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eIP55\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFluid Viscosity (Allowed)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50–2000 cst at working temperature\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e-10°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eRelative Humidity (Max)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e90%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eWorking Cycle\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eContinuous — no limitations under normal operating conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eSuction Hose (Min)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1\" diameter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eDelivery Hose (Min)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1\/2\" diameter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eNoise Level\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eMax 70 dB(A) at 1 metre\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eSelf-priming — able to draw oil from the tank even when the suction hose is empty on start-up\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eEquipped with bypass valve for automatic pressure relief\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIP55 motor protection class — suitable for demanding professional workshop environments\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eContinuous duty cycle under normal operating conditions — no work cycle time limit\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eExcellent suction capacity — flow rate\/back pressure curve remains stable even at high suction pressure values\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMultiple installation orientations supported — horizontal base, pump body upwards, or pump body aside\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eAlso available in 380V\/50Hz (DITI17320141) and single-phase 120V\/60Hz US configuration (DITI17320180)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eThe information contained in this data sheet is based on data considered to be accurate. No warranty is expressed or implied regarding the accuracy of this data. Product specifications and availability are subject to change without notice. Lube Control Pty Ltd accepts no responsibility for any loss or damage arising from the use of this information.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBE CONTROL","offers":[{"title":"240 Volt High Flow Gear Oil Pump","offer_id":50280589099283,"sku":"DITI17320140","price":905.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/DITI17320140.png?v=1736314379"},{"product_id":"trico-drum-pump-filtration-system-motors","title":"TRICO Drum Pump Filtration System Motors (P.O.A)","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\u003cstrong\u003eThe Trico 30018\u003c\/strong\u003e is a 1.1HP electric drum pump motor designed to drive the pump shaft of Trico Drum Pump Filtration Systems. Operating at 110–120V \/ 50–60Hz with a totally enclosed fan cooled (TEFC) motor and IP54 protection class, it is interchangeable with multiple Trico drum pump designs — only one motor is needed across multiple drum pumps. The electric motor cannot be operated continuously and should not run for more than 30 minutes without a cooldown period.\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e30018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eAmps\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e8.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e825W \/ 1.1HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eTEFC (IP54)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eHazardous Duty Rated\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMax Continuous Run Time\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e30 minutes (cooldown required after each cycle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e12.7 lbs (5.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eInterchangeable with multiple Trico Drum Pump Filtration System designs — one motor suits multiple drum pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eTotally Enclosed Fan Cooled (TEFC) motor with IP54 protection and thermal overload switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCompatible with Trico Drum Pump Filtration System (30035) and Low-Viscosity drum pump range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eNot rated for use with flammable or combustible materials or in hazardous duty areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\u003cstrong\u003eThe Trico 30021\u003c\/strong\u003e is a 1.1HP electric drum pump motor designed to drive the pump shaft of Trico Drum Pump Filtration Systems. Operating at 220–230V \/ 50–60Hz with a totally enclosed fan cooled (TEFC) motor and IP54 protection class, it is interchangeable with multiple Trico drum pump designs — only one motor is needed across multiple drum pumps. The electric motor cannot be operated continuously and should not run for more than 30 minutes without a cooldown period.\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e30021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eAmps\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e825W \/ 1.1HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eTEFC (IP54)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eHazardous Duty Rated\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMax Continuous Run Time\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e30 minutes (cooldown required after each cycle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e12.7 lbs (5.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eInterchangeable with multiple Trico Drum Pump Filtration System designs — one motor suits multiple drum pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eTotally Enclosed Fan Cooled (TEFC) motor with IP54 protection and thermal overload switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCompatible with Trico Drum Pump Filtration System (30035) and Low-Viscosity drum pump range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eNot rated for use with flammable or combustible materials or in hazardous duty areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\u003cstrong\u003eThe Trico 30019\u003c\/strong\u003e is a 3\/4HP pneumatic drum pump motor designed to drive the pump shaft of Trico Drum Pump Filtration Systems via compressed air. With a recommended operating pressure of 90 psi at 28 CFM and a maximum inlet pressure of 100 psi, it is interchangeable with multiple Trico drum pump designs — only one motor is needed across multiple drum pumps. A Filter Lubricator Regulator (FLR) with SAE 10 weight oil must always be used in the air supply line to remove water and lubricate the motor.\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e30019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e3\/4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eRecommended Operating Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e90 psi @ 28 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMaximum Inlet Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e100 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eAir Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e28 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eAirline Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMinimum Hose Size\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMax Noise Level\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e87 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e3.4 lbs (1.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003ePneumatic operation — no electrical power required, suitable for environments where electric motors are restricted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eInterchangeable with multiple Trico Drum Pump Filtration System designs — one motor suits multiple drum pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCompatible with Trico Drum Pump Filtration System (30035) and Low-Viscosity drum pump range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eA Filter Lubricator Regulator (FLR) with SAE 10 weight oil must be installed in the air supply line to prevent corrosion and ensure correct lubrication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eThe information contained in this data sheet is based on data considered to be accurate. No warranty is expressed or implied regarding the accuracy of this data. Product specifications and availability are subject to change without notice. Lube Control Pty Ltd accepts no responsibility for any loss or damage arising from the use of this information.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBECONTROL","offers":[{"title":"Electric Motor { Motor Type ( 110V 50-60 Hz 8.5 A)-Motor (1.10 HP @ 10 000 RPM)-Flow Rate(up to 7.25 GPM)}","offer_id":51739958739219,"sku":"30018","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Pneumatic Motor { Motor(3\/4 HP @ 8000 RPM) -Inlet Pressure (100 PSI Max @ 28 CFM)-Stall Pressure(50 PSI)-Flow Rate(up to 6 GPM)}","offer_id":51739958771987,"sku":"30019","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Electric Motor - 220V{Motor Type(220 V 50 Hz)-Motor (1.10 HP @ 10 000 RPM)-Flow Rate(up to 7.25 GPM)}","offer_id":51739958804755,"sku":"30021","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/Untitleddesign_49.png?v=1747194581"},{"product_id":"trico-drum-pump-recirculation-kit","title":"TRICO Drum Pump Recirculation Kit (P.O.A)","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003eThe Trico Drum Pump Recirculation Kit (Part #30032) is designed to directly filter and recirculate lubricants from a standard 55-gallon drum back into the same drum, handling lubricants with a viscosity of 1250 cSt (5500 SUS) and below. Used in conjunction with the Trico Drum Pump Filtration System (P\/N 30035) and a compatible drum pump motor, oil can be filtered continuously for as long as required with this self-contained kit. The kit also allows the system to be quickly converted back to normal dispensing use via the included plug connection.\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e30032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCompatible Drum Size\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eStandard 55-gallon drum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMaximum Fluid Viscosity\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1250 cSt (5500 SUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMinimum Filtration Level (Higher Viscosity Oil)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e10 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMinimum Filtration Level (Hydraulic Oil)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e3 microns at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eRequired Assembly Tool\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e2 x 2.5\" adjustable wrenches or pipe wrenches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eIncluded Components\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003e(A) Watchdog EX Breather\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003e(B) Male Quick Coupler Hose Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003e(C) Plug Connection for Equipment \/ Dispensing Nozzle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003e(D) Ball Valve \/ Wye Fitting \/ Plug Connector \/ Drum Adapter Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eRequired Items (Sold Separately)\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003e30035\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDrum Pump Filtration System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003e30018\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDrum Pump Electric Motor, 1.1Hp, 110–120V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003e30021\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDrum Pump Electric Motor, 1.1Hp, 220–230V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003e30019\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDrum Pump Pneumatic Motor, 3\/4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eFilters and recirculates lubricant directly within the same 55-gallon drum — no additional container required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCompatible with lubricants up to 1250 cSt (5500 SUS) viscosity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eHydraulic oils can be filtered down to 3 microns at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIncludes Watchdog EX Breather to protect drum contents from moisture and airborne contaminants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eBall valve on drum adapter assembly prevents back flow of oil to the desiccant breather during recirculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003ePlug Connection (C) allows quick conversion back to normal dispensing use or direct equipment connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMotor is interchangeable with different Trico Drum Pump Filtration System designs — one motor can be used across multiple drum pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eWhen filtering higher viscosity oils such as ISO 460 and ISO 680, use of a drum heating blanket is required to reduce viscosity to within system limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003e\u003cspan _mstmutation=\"1\" _msttexthash=\"5001269\" _msthash=\"0\" style=\"\"\u003eBu veri formunda yer alan bilgiler, doğru olduğu düşünülen verilere dayanmaktadır.\u003c\/span\u003e No warranty is expressed or implied regarding the accuracy of this data. Product specifications and availability are subject to change without notice. Lube Control Pty Ltd accepts no responsibility for any loss or damage arising from the use of this information.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBECONTROL","offers":[{"title":"Default Title","offer_id":51739970339091,"sku":"30032","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/TRICODrumPumpRecirculationKit.png?v=1747195912"}],"url":"https:\/\/www.lubecontrolshop.com.au\/collections\/electrical-oil-pumps.oembed","provider":"LUBECONTROL","version":"1.0","type":"link"}