{"title":"ILC MINI MAX Spare Parts","description":"","products":[{"product_id":"ilc-minimax-fixed-pump-element","title":"ILC MINIMAX fixed pump element","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\nThe Fixed Metering Device Pumping Element (00.900.0) is designed for use with the Mini-Max Series Piston Electric Pump, delivering a consistent fixed flow rate of 120 mm³ per cycle to supply progressive metering devices. Built with a safety valve that automatically discharges excess pressure over 200 bar, this element ensures reliable and safe operation in demanding centralised lubrication systems. Its fixed output makes it the ideal choice where a stable, pre-set lubrication rate is required without the need for field adjustment.\n\u003c\/p\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eProduct Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e00.900.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eType\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eFixed Metering Device Pumping Element\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFlow Rate per Cycle\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e120 mm³\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eFlow Rate Setting\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eFixed (non-adjustable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eSafety Valve\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eYes — auto-discharge above 200 bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCompatible Pump Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eMini-Max Series Piston Electric Pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eInstallation Torque\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e21 Nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eInitial Fittings\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eMust be ordered separately\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eFixed 120 mm³\/cycle output for consistent, predictable lubrication\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIntegrated safety valve automatically relieves pressure above 200 bar\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eDesigned to supply progressive metering devices with a high flow rate\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eEasy field installation — insert into any available pump seat after removing the yellow cap\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCompatible with the full Mini-Max Series Piston Electric Pump range\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eApplications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCentralised lubrication systems requiring fixed-output pumping elements\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eFeeding progressive metering devices in industrial machinery\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eReplacement or additional pumping element for existing Mini-Max pump installations\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eNote: Initial fittings are not included and must be ordered separately. Installation torque must be 21 Nm to ensure proper tightening and gasket seal. Refer to Mini-Max Series Manual Edition 15603-01-REV.03 for full installation guidance.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBECONTROL","offers":[{"title":"Default Title","offer_id":51892359594259,"sku":"00.900.0","price":230.28,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/00.900.0.png?v=1749527998"},{"product_id":"ilc-minimax-adjustable-element","title":"ILC MINIMAX adjustable element","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003eThe 00.900.3 is the adjustable metering pumping element for the ILC MINI-MAX Series piston electric pump, designed to supply progressive metering devices. Unlike fixed-flow elements, the 00.900.3 features a built-in safety valve that automatically discharges excess pressure over 200 bar, and its flow rate is user-adjustable from 0 to 120 mm³ per cycle by loosening the counter nut and rotating the adjustment screw. It measures 112.5 mm in total length and 66 mm in height, with a 1\/4\"  BSP inlet thread. The initial fittings must be ordered separately, and a closing torque of 21 Nm must be applied to ensure proper tightening and gasket seal.\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid rgb(216, 216, 216); margin-bottom: 32px; height: 207.854px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18.8958px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 18.8958px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 18.8958px;\"\u003e00.900.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 37.7917px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 37.7917px;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 37.7917px;\"\u003eAdjustable metering pumping element — for progressive metering devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.8958px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 18.8958px;\"\u003eFlow Rate per Cycle\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 18.8958px;\"\u003e0 – 120 mm³ (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 37.7917px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 37.7917px;\"\u003eSafety Valve\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 37.7917px;\"\u003eYes — automatically discharges excess pressure over 200 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.8958px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 18.8958px;\"\u003eInlet Thread\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 18.8958px;\"\u003e1\/4\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.8958px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 18.8958px;\"\u003eTotal Length\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 18.8958px;\"\u003e112.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.8958px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 18.8958px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid rgb(216, 216, 216); font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 18.8958px;\"\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 37.7917px;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: rgb(17, 17, 17); width: 38%; vertical-align: top; height: 37.7917px;\"\u003eInstallation Torque\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: rgb(68, 68, 68); vertical-align: top; height: 37.7917px;\"\u003e21 Nm (progressive metering device pumping elements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFlow Rate Adjustment Table\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 33%; vertical-align: top;\"\u003eSetting A (mm)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 33%; vertical-align: top;\"\u003eFlow Rate \/ Cycle\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 33%; vertical-align: top;\"\u003ePercentage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e23.6\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e120 mm³\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e22.4\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e0.09 cc\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e21.2\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e0.06 cc\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e20.1\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e0.03 cc\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e19.4\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e0.03 cc\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e17.5\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e0.00 cc\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eAdjustable flow rate from 0 to 120 mm³ per cycle — set by loosening the counter nut (Pos. C) and rotating the adjustment screw (Pos. B) clockwise to reduce or anticlockwise to increase output; retighten counter nut after setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eBuilt-in safety valve — automatically discharges excess pressure over 200 bar, protecting the system and progressive metering devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eConsiderably superior flow rate compared to single-point pumping elements — designed specifically for supplying DPX and other progressive metering devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eEasy field installation — remove the yellow cap from the desired seat position, insert and screw the element all the way in to 21 Nm torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n\u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCompatible with the ILC MINI-MAX Series piston electric pump — initial fittings must be ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eFor use with the ILC MINI-MAX Series piston electric pump. Initial fittings not included — must be ordered separately. Fixed-flow metering element also available: 00.900.0 (120 mm³\/cycle fixed). Reference: MINI-MAX Series Manual, Edition 15603-01-REV.03. Supplied by Lube Control Pty Ltd — call 1300 917 946 \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBECONTROL","offers":[{"title":"Default Title","offer_id":51892447772947,"sku":"00.900.3","price":256.68,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/00.900.3.png?v=1749528056"}],"url":"https:\/\/www.lubecontrolshop.com.au\/collections\/ilc-mini-max-spare-parts.oembed","provider":"LUBECONTROL","version":"1.0","type":"link"}