CisoLube DSP Divider Valve
The CISO DSP is a mono-block progressive grease and oil divider valve designed for applications where space is limited. Available in 6 to 22 outlets with a fixed output of 0.2 ml per outlet per cycle, it features unique cross-porting that allows any outlet to be plugged to double the output of the next outlet. Internal pistons move in a strict sequential order ā if one outlet becomes blocked, the entire sequence stops, triggering the overpressure relief valve as a built-in monitoring signal. Visual and electronic monitoring options are available, and the valve is rated to 300 bar with a maximum cycle rate of 200 cycles per minute.
Technical Specifications
| Number of Outlets | 6, 8, 10, 12, 18, 20, and 22 |
| Discharge per Outlet | 0.2 ml per cycle (fixed) |
| Maximum Pressure | 300 bar (30 MPa) |
| Maximum Cycle Rate | 200 cycles/min |
| Compatible Lubricants | Oil (minimum 46 cSt), Grease NLGI 000, 00, 0, 1, 2 |
| Inlet Thread | 1/8 BSP |
| Outlet Thread | M10 x 1.0 |
| Outlet Fittings | Conical check valve fitting required on each outlet |
| Material | Zinc-nickel (stainless steel available upon request) |
| Mounting Holes | 6.5 mm |
| Visual Monitoring | Optional (DSPVCP ā Visual Cycle Pin) |
| Electrical Monitoring | Optional (124581 ā Inductive PNP Proxy Sensor, 4-pin M12 x 1) |
Dimensions by Outlet Count
| 6 outlets (31N03) | A = 60 mm |
| 8 outlets (31N04) | A = 75 mm |
| 10 outlets (31N05) | A = 90 mm |
| 12 outlets (31N06) | A = 105 mm |
| 14 outlets (31N07) | A = 120 mm |
| 16 outlets (31N08) | A = 135 mm |
| 18 outlets (31N09) | A = 150 mm |
| 20 outlets (31N10) | A = 165 mm |
| 22 outlets (31N11) | A = 180 mm |
Features
| ā¢Mono-block construction ā compact footprint ideal for space-restricted installations |
| ā¢Unique cross-porting design ā any outlet can be plugged to double the discharge of the adjacent outlet, enabling flexible system configuration |
| ā¢Sequential piston operation ā pistons move in a fixed order; each dispenses only its predetermined volume before the next begins, ensuring precise and equal distribution |
| ā¢Built-in blockage detection ā if any outlet becomes blocked, the entire piston sequence stops and the overpressure relief valve exerts grease, providing a clear system fault signal |
| ā¢Optional visual monitoring via cycle pin (DSPVCP) or electronic monitoring via inductive PNP proxy sensor (124581) with 2 m cable in straight (124582) or elbow (124583) configuration |
| ā¢Stainless steel construction available upon request ā standard finish is zinc-nickel |
Compatible Inlet & Outlet Fittings
| ā¢3T1002 ā Divider inlet fitting with 1/8 BSP grease nipple |
| ā¢BFDI1/8BSP ā Banjo divider inlet fitting with 1/8 BSP grease nipple |
| ā¢CVDDVXM10 ā Check valve straight M10 male x M10 female |
| ā¢4MMCVFPU ā Check valve straight M10 male x 4 mm tube push-in fitting |
| ā¢6MMCVFPU ā Check valve straight M10 male x 6 mm tube push-in fitting |
| ā¢CV6M10 ā Check valve straight M10 male x 6 mm tube compression fitting |
| ā¢CV6M10SS ā Stainless check valve straight M10 male x 6 mm tube compression fitting |
| ā¢CFNV6M ā Check valve straight M10 male x 6 mm tube compression fitting ā Silver |
| ā¢CFNV6MBL ā Check valve straight M10 male x 6 mm tube compression fitting ā Black |
Each outlet must be fitted with a conical check valve fitting. Stainless steel body available upon request. Supplied by Lube Control Pty Ltd ā call 1300 917 946 or visit lubecontrol.com.au for outlet count selection, fitting advice, and monitoring options.
Ā
Out of stock ? / Ordering a large item?
Contact our team to confirm availability, delivery options, and customised freight costs for oversized or heavy products before placing your order.
sales@lubecontrol.com.au
1300 917 946
+61 8 8298 5563
Technical Documents
CisoLube-DSP Grease Divider Valve
Download PDFDisclaimer
Product details and specifications are for reference only and subject to change without notice. Customers must independently verify all technical data and OEM approvals directly with the manufacturer prior to purchase. We accept no liability for any errors, omissions, or damages arising from reliance on this information.