CisoLube - GT PLUS Pump 240 Voltage
The CisoLube GT Plus 240V is the heart of a progressive lubrication system engineered to accurately distribute oil or grease (up to NLGI 2) to multiple machine lubrication points. Running on 240V AC mains power, it is built for both intermittent and continuous operation and delivers up to 300 bar of outlet pressure — enough to reach grease points more than 20m away. The unit comes complete with a built-in motor, gearbox, and integrated programmable timer, and is available with a transparent acrylic reservoir in five sizes from 2L to 12L. An IP67-rated housing and an operating range of −50°C to +90°C ensure reliable performance in the most demanding industrial environments.
Technical Specifications
| Part Number (Base Unit) | CISOGTBASE240V |
| Voltage | 240V AC (order code suffix: 240V) |
| Maximum Outlet Pressure | 30 MPa (300 bar) |
| Reservoir Options | 2L | 4L | 6L | 8L | 12L — transparent acrylic |
| Pumping Elements | 1 (standard) — expandable up to 5 |
| Flow Rate per Element | 4 ml/min (adjustable with washers: −1 ml/min per washer, max 2 washers) |
| Compatible Lubricants | Oil (min. 46 cSt viscosity) | Grease NLGI 000, 00, 0, 1, 2 |
| Fill Port | Grease nipple (for grease) | Filter strainer (for oil) |
| Operating Temperature | −50°C to +90°C |
| Ingress Protection | IP67 (dust-tight and waterproof) |
| Operating Modes | Intermittent or continuous |
| Connector | 7-pin Tyco bayonet plug |
Features
| •300 bar maximum outlet pressure — capable of reaching lubrication points more than 20m from the pump unit |
| •Mains-powered 240V AC operation — ideal for fixed plant and workshop installations with permanent power supply |
| •Built-in motor, gearbox, and integrated control timer with LED display — no external controller required for standalone operation |
| •Password-protected timer with manual override and pre-lube capability for on-demand lubrication without altering the programmed cycle |
| •Low-level and pulse alarm with combined LED indicator and audible buzzer — alerts operators before lubricant runs out or a cycle fault occurs |
| •Transparent acrylic reservoir in five size options (2L to 12L) for continuous visual level monitoring without disassembly |
| •Dual fill port configuration — grease nipple for grease applications and filter strainer for oil applications |
| •Expandable from 1 to 5 pumping elements; flow rate fine-tunable with adjustment washers (−1 ml/min per washer, up to 2 washers) |
| •IP67-rated housing engineered for extreme environments — operates reliably from −50°C to +90°C |
| •7-pin Tyco bayonet plug for secure, weather-resistant electrical connection |
Applications
| •Fixed plant, workshops, and factory machinery with permanent 240V AC mains power requiring centralised automatic lubrication |
| •Mining, construction, and quarrying equipment operating in harsh, dusty, or wet environments where IP67 protection is essential |
| •Multi-point progressive lubrication systems serving bearings, pins, bushings, and open gears across large machine structures |
| •Cold-climate or high-temperature environments (−50°C to +90°C) where conventional lubricators fail |
| •Standalone timer-controlled installations as well as PLC-integrated systems requiring precise, scheduled intermittent or continuous lubrication cycles |
Compatible with oil (min. 46 cSt) and grease up to NLGI 2. Flow rate adjustment washers reduce output by 1 ml/min each; maximum 2 washers per element. For divider valve selection, accessory cables, or system design assistance contact Lube Control on 1300 917 946 or sales@lubecontrol.com.au.
Disclaimer
Technical specifications may change. Please confirm with the manufacturer.
Out of stock?
Contact our team to confirm availability and delivery options.
sales@lubecontrol.com.au
1300 917 946
+61 8298 5563