{"product_id":"memolub-hps-plc-24v-pump","title":"Memolub PLC Pump","description":"\u003ciframe src=\"https:\/\/drive.google.com\/file\/d\/11pG10KbY88BpIi9siC9SawxMZUfH6BMr\/preview\" width=\"300\" height=\"400\"\u003e\u003c\/iframe\u003e\n\n\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003eThe Memolub PLCD Series is a PLC-controlled automatic single-point lubricator designed for seamless integration into externally powered industrial machinery and automation systems. Powered entirely by an external 24V AC\/DC supply — no internal batteries required — the PLCD and PLCD Plus variants deliver precise, on-demand lubrication of grease and oil to bearings, open gears, and other critical lube points directly from your existing PLC or timer device. Available in 120cc, 240cc, and 480cc cartridge sizes as well as a 500ml refillable oil reservoir, the PLCD Series is built for continuous industrial operation with short-circuit protection and a transparent housing for visual lubricant level monitoring.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCartridge Sizes\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e120cc (4 oz)  |  240cc (8.1 oz)  |  480cc (16.2 oz)  |  OILR-500 Refillable Oil Reservoir 500ml (16.9 oz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003ePower Source\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eExternal power supply (min. 15W \/ 0.6A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eInput Voltage — PLCD\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eInput Voltage — PLCD Plus\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e24V DC nominal (adjustable within 6–36V DC range upon request)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCable\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eVTLB RD H03VV-F 2 × 0.75mm² (200mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eShort Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eStroke Duration\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e5 seconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMinimum Stroke Interval\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e20 seconds (oils only); minimum 15 minutes recommended for greases\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eVolume per Stroke\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e0.6 cc\/cycle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMaximum Outlet Pressure\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e25 bar \/ 350 PSI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e-15°C to 50°C (use lubricant adapted for low temperatures where required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eLubricant Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eOil and Grease up to NLGI #2; oil base viscosity 100–460 cSt\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eThread Connection\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eBSP 1\/4 (base)  |  BSP 1\/8 (remote lube point)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eMax. Remote Installation Distance\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eSingle point: 10m  |  Multipoint (2–4 outlets): 6m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eOperating Modes\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eIntermittent (grease \u0026amp; oil)  |  Continuous (oils only; max. 10 pumping cycles per input signal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eNoise Level\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eLeq \u0026lt; 70 dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eCertifications\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eCE (2006\/42\/EC Machinery Directive)  |  UKCA  |  EAC (TR CU 010\/2011)  |  WEEE compliant\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eFully externally powered — no internal batteries required; operates directly from customer PLC or timer device at 24V AC\/DC\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIntermittent mode for grease and oil (input signal 5–25s, minimum 25s off-time) and continuous fast mode for oils only (up to 10 pumping cycles per input signal)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eTransparent housing for at-a-glance lubricant level monitoring without disassembly\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eLED status indicator: green light confirms a successful pumping cycle; red light signals gearbox\/motor fault\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eModular PLCD Memo base design — base remains fixed at the lube point while the lubricator body is removed for quick cartridge replacement\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eSupports direct, remote (up to 10m single point), and multipoint installation (up to 4 outlets) with quick-connect hose fittings\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eWiring supports limit switch feedback integration; compatible with standard PLC output or timer device\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eEasy function check at any time: power OFF then ON from the PLC triggers a single test expulsion\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eCompatible with 120cc, 240cc, and 480cc lubricant cartridges and the OILR-500 refillable oil reservoir; battery seal removable for 480cc cartridges\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMaintenance-free design; can be cleaned with compressed air or a slightly damp cloth — no solvents required\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eApplications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003ePLC-controlled production machinery requiring synchronised, on-demand lubrication triggered by machine cycles\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eRolling element bearings and open gears on automated lines where lubrication must be coordinated with machine operation\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eApplications requiring continuous oil lubrication at high cycle rates, such as high-speed spindles and conveyors\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eRemote or hard-to-access lube points served via hose lines and quick-connect fittings up to 10m away\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMultipoint lubrication setups serving up to 4 outlets from a single PLCD unit via distributor block\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eAlways use only manufacturer-recommended lubricant cartridges. Do not open the housing — the internal spring is under load. Continuous mode is for oils only; use intermittent mode for greases with a minimum 15-minute interval between strokes. For viscosity levels outside 100–460 cSt or voltage requirements outside the standard range, contact your local distributor.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBECONTROL","offers":[{"title":"Memolub HPS\/PLC 120cc 24v Pump","offer_id":50906507182355,"sku":"HPS-S\/PLC","price":479.26,"currency_code":"AUD","in_stock":true},{"title":"Memolub HPS\/PLC 240cc 24v Pump","offer_id":50906507215123,"sku":"HPS-M\/PLC","price":509.69,"currency_code":"AUD","in_stock":true},{"title":"Memolub HPS\/PLC 480cc 24v Pump","offer_id":50906507247891,"sku":"HPS-G\/PLC","price":600.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/PLCD-480CC-NEW.png?v=1744768960","url":"https:\/\/www.lubecontrolshop.com.au\/products\/memolub-hps-plc-24v-pump","provider":"LUBECONTROL","version":"1.0","type":"link"}