{"product_id":"putz-standard-desiccant-breather","title":"Pütz Standard Desiccant Breather","description":"\u003c!-- SHOPIFY PRODUCT DESCRIPTION — paste everything below into the HTML source editor --\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.75; color: #444; margin: 0 0 32px 0;\"\u003e\nThe Pütz Standard Desiccant Breather range provides high-efficiency moisture and particulate control for hydraulic reservoirs, gearboxes, IBCs, transformers, and lubrication storage systems. Ideal for oil reservoirs with high air flow, each breather replaces a standard vent cap or paper filter — ensuring all incoming air is filtered to 3-micron absolute and dried through indicating silica gel (blue) to prevent water ingress and airborne contamination. Available in four sizes to suit applications from small gearboxes to large industrial systems.\n\u003c\/p\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eTechnical Specifications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; width: 38%; vertical-align: top;\"\u003eParticulate Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e3 μm absolute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eMoisture Control\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eIndicating silica gel — colour change blue → pink when saturated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eHousing\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eGaskets\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eBuna-N\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e-20°C to +90°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eMaximum Humidity Exposure\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e100% RH\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eUV Resistance\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eHigh\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eService Life\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eDependent on humidity, airflow, and system cycling frequency — replace after 1 year or when silica gel turns pink\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eModel Selection\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f5f5f5;\"\u003e\n      \u003ctd style=\"padding: 10px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 12px; color: #111; vertical-align: top;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 12px; color: #111; vertical-align: top;\"\u003eConnection (NPT\/BSP male)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 12px; color: #111; vertical-align: top;\"\u003eAirflow Capacity (L\/min)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 12px; color: #111; vertical-align: top;\"\u003eSilica Gel (g)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 12px; color: #111; vertical-align: top;\"\u003eDimensions W x H (mm)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 12px; color: #111; vertical-align: top;\"\u003eTypical Applications\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eDB-PUTZ-ST1\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e3\/8\"\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e10–40\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e50 g\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e63.5 x 89\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eSmall gearboxes, reservoirs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eDB-PUTZ-ST2\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1\"\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e40–100\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e150 g\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e101.5 x 155\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eHydraulic reservoirs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eDB-PUTZ-ST3\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1\"\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e100–200\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e300 g\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e101 x 206\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eMobile equipment\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; font-size: 13.5px; color: #111; vertical-align: top;\"\u003eDB-PUTZ-ST4\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e1\"\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e150–250\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e500 g\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e101.5 x 257\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003eLarge industrial systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eFeatures\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIndicating silica gel (blue) provides clear visual saturation monitoring — replace when gel turns pink\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003e3-micron absolute particulate filtration — removes fine dust and airborne contaminants from all incoming air\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eNo check valve — airflow passes freely through the breather whenever the equipment breathes, making it ideal for high airflow oil reservoirs\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIntegrated standpipe provides even airflow distribution and vibration resistance\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eOutgoing air vents through the same filtration path — protects silica gel from oil mist and extends service life\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eRugged impact-resistant polycarbonate housing — suitable for industrial and mobile equipment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eThreaded multi-fit mounting for fast installation on reservoirs, gearboxes and IBCs — replaces standard vent cap or paper filter\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eApplications\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eHydraulic power units\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eGearboxes and bearing housings\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eLubricant storage drums and totes\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eTransformers\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eMobile equipment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eIndustrial machinery exposed to dust or humidity\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 12px; font-weight: bold; color: #111; letter-spacing: .1em; text-transform: uppercase; margin: 0 0 10px 0;\"\u003eInstallation \u0026amp; Maintenance\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #d8d8d8; margin-bottom: 32px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eRemove existing vent or filler cap and ensure mounting surface is clean and free of debris\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eThread breather onto port hand-tight — do not overtighten\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eInspect silica gel colour regularly — replace breather after 1 year or when gel reaches full saturation (turns pink)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; border-bottom: 1px solid #d8d8d8; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eAvoid exposure to direct oil mist to maximise service life\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 11px 16px; font-size: 13.5px; color: #444; vertical-align: top;\"\u003e\n        \u003cspan style=\"color: #555; margin-right: 10px;\"\u003e•\u003c\/span\u003eStore unused breathers indoors in a sealed package\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size: 11px; color: #999; margin: 0;\"\u003eFor low airflow oil reservoirs, see the Pütz Check Valve Breather range. Contact Lube Control Pty Ltd on 1300 917 946 or sales@lubecontrol.com.au for further assistance.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"LUBECONTROL","offers":[{"title":"Pütz Standard Desiccant Breather 3\/8\" Multi-Fit (NPT-BSPP-BSPT) 63.5mm x 89mm","offer_id":52942877950227,"sku":"DB-PUTZ-ST1","price":99.66,"currency_code":"AUD","in_stock":true},{"title":"Pütz Standard Desiccant Breather 1\" Multi-Fit (NPT-BSPP-BSPT) 101.5mm x 155mm","offer_id":52942877982995,"sku":"DB-PUTZ-ST2","price":129.9,"currency_code":"AUD","in_stock":true},{"title":"Pütz Standard Desiccant Breather 1\" Multi-Fit (NPT-BSPP-BSPT) 101.5mm x 206mm","offer_id":52942878015763,"sku":"DB-PUTZ-ST3","price":139.53,"currency_code":"AUD","in_stock":true},{"title":"Pütz Standard Desiccant Breather 1\" Multi-Fit (NPT-BSPP-BSPT) 101.5mm x 257mm","offer_id":52942878048531,"sku":"DB-PUTZ-ST4","price":178.71,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/4898\/9459\/files\/Putz_cv_renge..png?v=1770942488","url":"https:\/\/www.lubecontrolshop.com.au\/products\/putz-standard-desiccant-breather","provider":"LUBECONTROL","version":"1.0","type":"link"}